Flange Connection System

The Lin Sing flange connection system complies in full with DW144 and has been independently tested to the DW/TM1 procedure by Ir HN Lam of the University of Hong Kong. Four profiles across three sizes cover joint classifications J2 to J5 and Pressure Classes A, B and C.

DW144DW/TM1J2 – J5Class A · B · C
HLGDuct wallFlange profileGasketDrive clip
Flange joint — schematic section

Profile dimensions

Table A
Flange profiles LS2 – LS5
ModelNominal sizeGaugeHLG
LS225 mmTo confirmTo confirmTo confirmTo confirm
LS330 mmTo confirmTo confirmTo confirmTo confirm
LS440 mm1.0 mmTo confirmTo confirmTo confirm
LS540 mm1.2 mmTo confirmTo confirmTo confirm

Four profiles, three sizes. LS4 and LS5 share the 40 mm nominal size and differ in gauge (1.0 mm vs 1.2 mm). The existing leaflet reads "Four flange sizes 25mm, 30mm and 40mm" — four models against three figures. Corrected here.

Test results

Table B

Independently tested by Ir HN Lam, The University of Hong Kong, to the DW/TM1 procedure.

Joint classification × pressure class
Joint classPressure Class APressure Class BPressure Class C
J2To confirmTo confirmTo confirm
J3To confirmTo confirmTo confirm
J4To confirmTo confirmTo confirm
J5To confirmTo confirmTo confirm

Values to be transcribed from the test report. This is the most persuasive block on the site, so no figure is estimated here — the numbers come straight off the HKU report.

Corner pieces

Table C
ModelFor profileThicknessLength
LS20CLS2To confirmTo confirm
LS30CLS3To confirmTo confirm
LS40CLS4 / LS5To confirmTo confirm

Fabrication sequence

Six steps
01

Cut the profile

Cut flange profile to duct edge length, four pieces per joint.

02

Assemble the frame

Arrange the four lengths into a rectangular frame ready for corner pieces.

03

Insert corner pieces

Insert the matching corner piece (LS20C / LS30C / LS40C) at each of the four corners.

04

Fit to duct

Slide the assembled frame onto the duct end and align to the duct wall.

05

Spot weld or rivet

Spot weld or rivet along the duct wall to lock the flange to the duct.

06

Seal

Apply sealant to the inside face. The joint is then ready for site installation.

Site installation

On site

Overlap gasket by 30 mm

Gasket ends must overlap by at least 30 mm — do not butt-joint.

Reinforce corners above 1000 Pa

Where system pressure exceeds 1000 Pa, add supplementary corner bolts.

Hand-tighten bolts first

Hand-tighten all bolts and confirm alignment on all four sides before driving the clips.

Clip driving sequence

Drive clips from the centre outwards to distribute clamping pressure evenly.

Downloads

Documents
  • Flange system specification (PDF)In preparation — available on request
  • DW/TM1 test reportIn preparation — available on request
  • CAD section file (DWG)In preparation — available on request